ICD-10-PCS 2027 procedure code
0RW437ZRevision of Autologous Tissue Substitute in Cervicothoracic Vertebral Joint, Percutaneous Approach
Short description: Revision of Autol Sub in C-thor Jt, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0RW437Z
0RW437Z is the ICD-10-PCS code for a revision procedure on the cervicothoracic vertebral joint using a percutaneous approach with autologous tissue substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other arthrotomy, other specified sites, the ICD-9-CM procedure title it maps to (80.19).
For a different body part, codes include 0RW037Z (occipital-cervical joint), 0RW137Z (cervical vertebral joint), 0RW337Z (cervical vertebral disc), 0RW537Z (cervicothoracic vertebral disc), 0RW637Z (thoracic vertebral joint), 0RW937Z (thoracic vertebral disc) and 22 more.
The same procedure with a different approach is coded 0RW407Z (open), 0RW447Z (percutaneous endoscopic) and 0RW4X7Z (external).
With a different device, use 0RW430Z (drainage device), 0RW433Z (infusion device), 0RW434Z (internal fixation device), 0RW438Z (spacer), 0RW43AZ (interbody fusion device), 0RW43JZ (synthetic substitute) and 1 more.
It is an operating-room procedure in the MS-DRG logic for DRG 515 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with MCC), DRG 516 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with CC) and DRG 517 (Other Musculoskeletal System and Connective Tissue O.R. Procedures without CC/MCC), under the surgical category “Other Musculoskeletal System and Connective Tissue O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- RUpper Joints
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 4Cervicothoracic Vertebral Joint
Includes: Cervicothoracic facet joint
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 7Autologous Tissue Substitute
Includes: Autograft; Cultured epidermal cell autograft; Epicel(R) cultured epidermal autograft
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 0RW037ZOccipital-cervical Joint
- 0RW137ZCervical Vertebral Joint
- 0RW337ZCervical Vertebral Disc
- 0RW537ZCervicothoracic Vertebral Disc
- 0RW637ZThoracic Vertebral Joint
- 0RW937ZThoracic Vertebral Disc
- 0RWA37ZThoracolumbar Vertebral Joint
- 0RWB37ZThoracolumbar Vertebral Disc
- 0RWC37ZTemporomandibular Joint, Right
- 0RWD37ZTemporomandibular Joint, Left
- 0RWE37ZSternoclavicular Joint, Right
- 0RWF37ZSternoclavicular Joint, Left
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Other Musculoskeletal System and Connective Tissue O.R. Procedures
ICD-9-CM equivalent
Converter →- 80.19Other arthrotomy, other specified sitesapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0RW437Z
Is 0RW437Z a valid ICD-10-PCS code for 2027?
- Yes. 0RW437Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0RW437Z an O.R. procedure?
- Yes. 0RW437Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0RW437Z group to?
- Depending on the principal diagnosis, 0RW437Z can group to MS-DRG 515, MS-DRG 516 and MS-DRG 517.
What is the ICD-9 procedure code for 0RW437Z?
- The CMS GEMs map 0RW437Z to ICD-9-CM 80.19 (Other arthrotomy, other specified sites).