ICD-10-PCS 2027 procedure code
0RWKXJ7Revision of Synthetic Substitute in Left Shoulder Joint, Glenoid Surface, External Approach
Short description: Revise Synth Sub in L Shoulder Jt, Glenoid, Extern
Code last changed in FY2022 (effective October 1, 2021). Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0RWKXJ7
0RWKXJ7 is the ICD-10-PCS code for a revision procedure on the left shoulder joint using an external approach with synthetic substitute (qualifier: glenoid surface). In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
For a different body part, codes include 0RWJXJ7 (right shoulder joint).
The same procedure with a different approach is coded 0RWK0J7 (open), 0RWK3J7 (percutaneous) and 0RWK4J7 (percutaneous endoscopic).
It doesn't appear in the MS-DRG procedure index, so on its own it doesn't change the DRG assignment.
It was added in FY2022, effective October 1, 2021.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- RUpper Joints
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- KShoulder Joint, Left
Includes: Glenohumeral joint; Glenoid ligament (labrum)
- 5. Approach
- XExternal
Procedures performed directly on the skin or mucous membrane and procedures performed indirectly by the application of external force through the skin or mucous membrane
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- 7Glenoid Surface
Other versions of this procedure
Different body part
Different approach
Different qualifier
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2022 (effective 10/1/2021): Added
- No changes since FY2022.
Common questions about 0RWKXJ7
Is 0RWKXJ7 a valid ICD-10-PCS code for 2027?
- Yes. 0RWKXJ7 is valid for inpatient procedures from October 1, 2026 through September 30, 2027.