ICD-10-PCS 2027 procedure code
0SW730ZRevision of Drainage Device in Right Sacroiliac Joint, Percutaneous Approach
Short description: Revision of Drain Dev in R Sacroiliac Jt, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0SW730Z
0SW730Z is the ICD-10-PCS code for a revision procedure on the right sacroiliac joint using a percutaneous approach with drainage device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other arthrotomy, other specified sites, the ICD-9-CM procedure title it maps to (80.19).
For a different body part, codes include 0SW030Z (lumbar vertebral joint), 0SW230Z (lumbar vertebral disc), 0SW330Z (lumbosacral joint), 0SW430Z (lumbosacral disc), 0SW530Z (sacrococcygeal joint), 0SW630Z (coccygeal joint) and 15 more.
The same procedure with a different approach is coded 0SW700Z (open), 0SW740Z (percutaneous endoscopic) and 0SW7X0Z (external).
With a different device, use 0SW733Z (infusion device), 0SW734Z (internal fixation device), 0SW737Z (autologous tissue substitute), 0SW738Z (spacer), 0SW73JZ (synthetic substitute) and 0SW73KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 515 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with MCC), DRG 516 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with CC) and DRG 517 (Other Musculoskeletal System and Connective Tissue O.R. Procedures without CC/MCC), under the surgical category “Other Musculoskeletal System and Connective Tissue O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- SLower Joints
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 7Sacroiliac Joint, Right
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 0Drainage Device
Includes: Cystostomy tube; Foley catheter; Percutaneous nephrostomy catheter; Thoracostomy tube
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Other Musculoskeletal System and Connective Tissue O.R. Procedures
ICD-9-CM equivalent
Converter →- 80.19Other arthrotomy, other specified sitesapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0SW730Z
Is 0SW730Z a valid ICD-10-PCS code for 2027?
- Yes. 0SW730Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0SW730Z an O.R. procedure?
- Yes. 0SW730Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0SW730Z group to?
- Depending on the principal diagnosis, 0SW730Z can group to MS-DRG 515, MS-DRG 516 and MS-DRG 517.
What is the ICD-9 procedure code for 0SW730Z?
- The CMS GEMs map 0SW730Z to ICD-9-CM 80.19 (Other arthrotomy, other specified sites).