Skip to content
Dx

ICD-10-PCS 2027 procedure code

0SW80JZRevision of Synthetic Substitute in Left Sacroiliac Joint, Open Approach

✓ Valid for 2027O.R. procedure

Short description: Revision of Synth Sub in L Sacroiliac Jt, Open Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0SW80JZ

0SW80JZ is the ICD-10-PCS code for a revision procedure on the left sacroiliac joint using an open approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to other arthrotomy, other specified sites, the ICD-9-CM procedure title it maps to (80.19).

For a different body part, codes include 0SW00JZ (lumbar vertebral joint), 0SW20JZ (lumbar vertebral disc), 0SW30JZ (lumbosacral joint), 0SW40JZ (lumbosacral disc), 0SW50JZ (sacrococcygeal joint), 0SW60JZ (coccygeal joint) and 23 more.

The same procedure with a different approach is coded 0SW83JZ (percutaneous), 0SW84JZ (percutaneous endoscopic) and 0SW8XJZ (external).

With a different device, use 0SW800Z (drainage device), 0SW803Z (infusion device), 0SW804Z (internal fixation device), 0SW807Z (autologous tissue substitute), 0SW808Z (spacer) and 0SW80KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 515 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with MCC), DRG 516 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with CC) and DRG 517 (Other Musculoskeletal System and Connective Tissue O.R. Procedures without CC/MCC), under the surgical category “Other Musculoskeletal System and Connective Tissue O.R. Procedures”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
SLower Joints
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
8Sacroiliac Joint, Left
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 80.19Other arthrotomy, other specified sitesapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0SW80JZ

Is 0SW80JZ a valid ICD-10-PCS code for 2027?

Yes. 0SW80JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0SW80JZ an O.R. procedure?

Yes. 0SW80JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0SW80JZ group to?

Depending on the principal diagnosis, 0SW80JZ can group to MS-DRG 515, MS-DRG 516 and MS-DRG 517.

What is the ICD-9 procedure code for 0SW80JZ?

The CMS GEMs map 0SW80JZ to ICD-9-CM 80.19 (Other arthrotomy, other specified sites).