ICD-10-PCS 2027 procedure code
0SW848ZRevision of Spacer in Left Sacroiliac Joint, Percutaneous Endoscopic Approach
Short description: Revision of Spacer in L Sacroiliac Jt, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0SW848Z
0SW848Z is the ICD-10-PCS code for a revision procedure on the left sacroiliac joint using a percutaneous endoscopic approach with spacer. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other arthrotomy, other specified sites, the ICD-9-CM procedure title it maps to (80.19).
For a different body part, codes include 0SW048Z (lumbar vertebral joint), 0SW348Z (lumbosacral joint), 0SW548Z (sacrococcygeal joint), 0SW648Z (coccygeal joint), 0SW748Z (right sacroiliac joint), 0SW948Z (right hip joint) and 13 more.
The same procedure with a different approach is coded 0SW808Z (open), 0SW838Z (percutaneous) and 0SW8X8Z (external).
With a different device, use 0SW840Z (drainage device), 0SW843Z (infusion device), 0SW844Z (internal fixation device), 0SW847Z (autologous tissue substitute), 0SW84JZ (synthetic substitute) and 0SW84KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 515 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with MCC), DRG 516 (Other Musculoskeletal System and Connective Tissue O.R. Procedures with CC) and DRG 517 (Other Musculoskeletal System and Connective Tissue O.R. Procedures without CC/MCC), under the surgical category “Other Musculoskeletal System and Connective Tissue O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- SLower Joints
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 8Sacroiliac Joint, Left
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- 8Spacer
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Other Musculoskeletal System and Connective Tissue O.R. Procedures
ICD-9-CM equivalent
Converter →- 80.19Other arthrotomy, other specified sitesapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0SW848Z
Is 0SW848Z a valid ICD-10-PCS code for 2027?
- Yes. 0SW848Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0SW848Z an O.R. procedure?
- Yes. 0SW848Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0SW848Z group to?
- Depending on the principal diagnosis, 0SW848Z can group to MS-DRG 515, MS-DRG 516 and MS-DRG 517.
What is the ICD-9 procedure code for 0SW848Z?
- The CMS GEMs map 0SW848Z to ICD-9-CM 80.19 (Other arthrotomy, other specified sites).