Skip to content
Dx

ICD-10-PCS 2027 procedure code

0SW94JZRevision of Synthetic Substitute in Right Hip Joint, Percutaneous Endoscopic Approach

✓ Valid for 2027O.R. procedure

Short description: Revision of Synth Sub in R Hip Jt, Perc Endo Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0SW94JZ

0SW94JZ is the ICD-10-PCS code for a revision procedure on the right hip joint using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to revision of hip replacement, not otherwise specified, the ICD-9-CM procedure title it maps to (81.53).

For a different body part, codes include 0SW04JZ (lumbar vertebral joint), 0SW24JZ (lumbar vertebral disc), 0SW34JZ (lumbosacral joint), 0SW44JZ (lumbosacral disc), 0SW54JZ (sacrococcygeal joint), 0SW64JZ (coccygeal joint) and 23 more.

The same procedure with a different approach is coded 0SW90JZ (open), 0SW93JZ (percutaneous) and 0SW9XJZ (external).

With a different device, use 0SW940Z (drainage device), 0SW943Z (infusion device), 0SW944Z (internal fixation device), 0SW945Z (external fixation device), 0SW947Z (autologous tissue substitute), 0SW948Z (spacer) and 1 more.

It is an operating-room procedure in the MS-DRG logic for DRG 449 (Revision of Hip or Knee Prosthesis), DRG 628 (Other Endocrine, Nutritional and Metabolic O.R. Procedures with MCC or Insertion of Antibiotic-eluting Bone Void Filler), DRG 629 (Other Endocrine, Nutritional and Metabolic O.R. Procedures with CC), DRG 630 (Other Endocrine, Nutritional and Metabolic O.R. Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC) and DRG 908 (Other O.R. Procedures for Injuries with CC), under the surgical categories “Revision of Hip or Knee Prosthesis”, “Other Endocrine, Nutritional and Metabolic O.R. Procedures”, “Other O.R. Procedures for Injuries” and 1 more.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
SLower Joints
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
9Hip Joint, Right
5. Approach
4Percutaneous Endoscopic

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Revision of Hip or Knee Prosthesis

MDC 24 · Multiple Significant Trauma · Limb Reattachment, Hip and Femur Procedures for Multiple Significant Trauma

ICD-9-CM equivalent

Converter →
  • 81.53Revision of hip replacement, not otherwise specifiedapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0SW94JZ

Is 0SW94JZ a valid ICD-10-PCS code for 2027?

Yes. 0SW94JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0SW94JZ an O.R. procedure?

Yes. 0SW94JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0SW94JZ group to?

Depending on the principal diagnosis, 0SW94JZ can group to MS-DRG 449, MS-DRG 628, MS-DRG 629, MS-DRG 630, MS-DRG 907 and MS-DRG 908.

What is the ICD-9 procedure code for 0SW94JZ?

The CMS GEMs map 0SW94JZ to ICD-9-CM 81.53 (Revision of hip replacement, not otherwise specified).