ICD-10-PCS 2027 procedure code
0TPD4JZRemoval of Synthetic Substitute from Urethra, Percutaneous Endoscopic Approach
Short description: Removal of Synth Sub from Urethra, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0TPD4JZ
0TPD4JZ is the ICD-10-PCS code for a removal procedure on the urethra using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, removal means taking out or off a device from a body part.
In plain terms, this corresponds to Urethrotomy, the ICD-9-CM procedure title it maps to (58.0).
For a different body part, codes include 0TP54JZ (kidney), 0TP94JZ (ureter) and 0TPB4JZ (bladder).
The same procedure with a different approach is coded 0TPD0JZ (open), 0TPD3JZ (percutaneous), 0TPD7JZ (via natural or artificial opening) and 0TPD8JZ (via natural or artificial opening endoscopic).
With a different device, use 0TPD40Z (drainage device), 0TPD42Z (monitoring device), 0TPD43Z (infusion device), 0TPD47Z (autologous tissue substitute), 0TPD4CZ (extraluminal device), 0TPD4DZ (intraluminal device) and 3 more.
It is an operating-room procedure in the MS-DRG logic for DRG 671 (Urethral Procedures with CC/MCC), DRG 672 (Urethral Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Urethral Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- TUrinary System
- 3. Operation
- PRemoval
Taking out or off a device from a body part
If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL
Includes: Drainage tube removal, cardiac pacemaker removal
- 4. Body Part
- DUrethra
Includes: Bulbourethral (Cowper's) gland; Cowper's (bulbourethral) gland; External urethral sphincter; Internal urethral sphincter; Membranous urethra; Penile urethra; Prostatic urethra
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 11 · Diseases and Disorders of the Kidney and Urinary Tract · Urethral Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 58.0Urethrotomyapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0TPD4JZ
Is 0TPD4JZ a valid ICD-10-PCS code for 2027?
- Yes. 0TPD4JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0TPD4JZ an O.R. procedure?
- Yes. 0TPD4JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0TPD4JZ group to?
- Depending on the principal diagnosis, 0TPD4JZ can group to MS-DRG 671, MS-DRG 672, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0TPD4JZ?
- The CMS GEMs map 0TPD4JZ to ICD-9-CM 58.0 (Urethrotomy).