ICD-10-PCS 2027 procedure code
0TR44JZReplacement of Left Kidney Pelvis with Synthetic Substitute, Percutaneous Endoscopic Approach
Short description: Replace L Kidney Pelvis w Synth Sub, Perc Endo
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0TR44JZ
0TR44JZ is the ICD-10-PCS code for a replacement procedure on the left kidney pelvis using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, replacement means putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part.
In plain terms, this corresponds to other repair of kidney, the ICD-9-CM procedure title it maps to (55.89).
For a different body part, codes include 0TR34JZ (right kidney pelvis), 0TR64JZ (right ureter), 0TR74JZ (left ureter), 0TRB4JZ (bladder), 0TRC4JZ (bladder neck) and 0TRD4JZ (urethra).
The same procedure with a different approach is coded 0TR40JZ (open), 0TR47JZ (via natural or artificial opening) and 0TR48JZ (via natural or artificial opening endoscopic).
With a different device, use 0TR447Z (autologous tissue substitute) and 0TR44KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 656 (Kidney and Ureter Procedures for Neoplasm with MCC), DRG 657 (Kidney and Ureter Procedures for Neoplasm with CC), DRG 658 (Kidney and Ureter Procedures for Neoplasm without CC/MCC), DRG 659 (Kidney and Ureter Procedures for Non-Neoplasm with MCC), DRG 660 (Kidney and Ureter Procedures for Non-Neoplasm with CC) and DRG 661 (Kidney and Ureter Procedures for Non-Neoplasm without CC/MCC), under the surgical categories “” and “Kidney and Ureter Procedures for Non-Neoplasm”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- TUrinary System
- 3. Operation
- RReplacement
Putting in or on biological or synthetic material that physically takes the place and/or function of all or a portion of a body part
The body part may have been taken out or replaced, or may be taken out, physically eradicated, or rendered nonfunctional during the Replacement procedure. A Removal procedure is coded for taking out the device used in a previous replacement procedure
Includes: Total hip replacement, bone graft, free skin graft
- 4. Body Part
- 4Kidney Pelvis, Left
Includes: Ureteropelvic junction (UPJ)
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 11 · Diseases and Disorders of the Kidney and Urinary Tract
MDC 11 · Diseases and Disorders of the Kidney and Urinary Tract · Kidney and Ureter Procedures for Non-Neoplasm
ICD-9-CM equivalent
Converter →- 55.89Other repair of kidneyapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0TR44JZ
Is 0TR44JZ a valid ICD-10-PCS code for 2027?
- Yes. 0TR44JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0TR44JZ an O.R. procedure?
- Yes. 0TR44JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0TR44JZ group to?
- Depending on the principal diagnosis, 0TR44JZ can group to MS-DRG 656, MS-DRG 657, MS-DRG 658, MS-DRG 659, MS-DRG 660 and MS-DRG 661.
What is the ICD-9 procedure code for 0TR44JZ?
- The CMS GEMs map 0TR44JZ to ICD-9-CM 55.89 (Other repair of kidney).