Skip to content
Dx

ICD-10-PCS 2027 procedure code

0TWD83ZRevision of Infusion Device in Urethra, Via Natural or Artificial Opening Endoscopic

✓ Valid for 2027O.R. procedure

Short description: Revision of Infusion Device in Urethra, Endo

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0TWD83Z

0TWD83Z is the ICD-10-PCS code for a revision procedure on the urethra using a via natural or artificial opening endoscopic approach with infusion device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Urethrotomy, the ICD-9-CM procedure title it maps to (58.0).

For a different body part, codes include 0TW583Z (kidney), 0TW983Z (ureter) and 0TWB83Z (bladder).

The same procedure with a different approach is coded 0TWD03Z (open), 0TWD33Z (percutaneous), 0TWD43Z (percutaneous endoscopic), 0TWD73Z (via natural or artificial opening) and 0TWDX3Z (external).

With a different device, use 0TWD80Z (drainage device), 0TWD82Z (monitoring device), 0TWD87Z (autologous tissue substitute), 0TWD8CZ (extraluminal device), 0TWD8DZ (intraluminal device), 0TWD8JZ (synthetic substitute) and 3 more.

It is an operating-room procedure in the MS-DRG logic for DRG 671 (Urethral Procedures with CC/MCC), DRG 672 (Urethral Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Urethral Procedures” and “Other O.R. Procedures for Injuries”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
TUrinary System
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
DUrethra

Includes: Bulbourethral (Cowper's) gland; Cowper's (bulbourethral) gland; External urethral sphincter; Internal urethral sphincter; Membranous urethra; Penile urethra; Prostatic urethra

5. Approach
8Via Natural or Artificial Opening Endoscopic

Entry of instrumentation through a natural or artificial external opening to reach and visualize the site of the procedure

6. Device
3Infusion Device

Includes: Ascenda Intrathecal Catheter; InDura, intrathecal catheter (1P) (spinal); Non-tunneled central venous catheter; Peripherally inserted central catheter (PICC); Tunneled spinal (intrathecal) catheter

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 11 · Diseases and Disorders of the Kidney and Urinary Tract · Urethral Procedures

ICD-9-CM equivalent

Converter →
  • 58.0Urethrotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0TWD83Z

Is 0TWD83Z a valid ICD-10-PCS code for 2027?

Yes. 0TWD83Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0TWD83Z an O.R. procedure?

Yes. 0TWD83Z is an O.R. procedure in MS-DRG v44.0.

What DRG does 0TWD83Z group to?

Depending on the principal diagnosis, 0TWD83Z can group to MS-DRG 671, MS-DRG 672, MS-DRG 907, MS-DRG 908 and MS-DRG 909.

What is the ICD-9 procedure code for 0TWD83Z?

The CMS GEMs map 0TWD83Z to ICD-9-CM 58.0 (Urethrotomy).