Skip to content
Dx

ICD-10-PCS 2027 procedure code

0UL73DZOcclusion of Bilateral Fallopian Tubes with Intraluminal Device, Percutaneous Approach

✓ Valid for 2027O.R. procedureFemale only

Short description: Occlusion Bi Fallopian Tube w Intralum Dev, Perc

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0UL73DZ

0UL73DZ is the ICD-10-PCS code for a occlusion procedure on the bilateral fallopian tubes using a percutaneous approach with intraluminal device. In ICD-10-PCS, occlusion means completely closing an orifice or the lumen of a tubular body part.

In plain terms, this corresponds to other bilateral destruction or occlusion of fallopian tubes, the ICD-9-CM procedure title it maps to (66.39).

For a different body part, codes include 0UL53DZ (right fallopian tube) and 0UL63DZ (left fallopian tube).

The same procedure with a different approach is coded 0UL70DZ (open), 0UL74DZ (percutaneous endoscopic), 0UL77DZ (via natural or artificial opening) and 0UL78DZ (via natural or artificial opening endoscopic).

With a different device, use 0UL73CZ (extraluminal device) and 0UL73ZZ (no device).

It is an operating-room procedure in the MS-DRG logic for DRG 744 (D&C, Conization, Laparoscopy and Tubal Interruption with CC/MCC), DRG 745 (D&C, Conization, Laparoscopy and Tubal Interruption without CC/MCC), DRG 783 (Cesarean Section with Sterilization with MCC), DRG 784 (Cesarean Section with Sterilization with CC), DRG 785 (Cesarean Section with Sterilization without CC/MCC) and DRG 796 (Vaginal Delivery with Sterilization and/or D&C with MCC), under the surgical categories “D&C, Conization, Laparoscopy and Tubal Interruption”, “Cesarean Section with Sterilization” and “Vaginal Delivery with Sterilization and/or D&C”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
UFemale Reproductive System
3. Operation
LOcclusion

Completely closing an orifice or the lumen of a tubular body part

The orifice can be a natural orifice or an artificially created orifice

Includes: Fallopian tube ligation, ligation of inferior vena cava

4. Body Part
7Fallopian Tubes, Bilateral
5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
DIntraluminal Device

Includes: Absolute Pro Vascular (OTW) Self-Expanding Stent System; Acculink (RX) Carotid Stent System; AFX(R) Endovascular AAA System; AneuRx(R) AAA Advantage(R); Assurant (Cobalt) stent; Carotid WALLSTENT(R) Monorail(R) Endoprosthesis; CoAxia NeuroFlo catheter; Colonic Z-Stent(R); Complete (SE) stent; Cook Zenith AAA Endovascular Graft; Driver stent (RX) (OTW); E-Luminexx(tm) (Biliary)(Vascular) Stent; Embolization coil(s); Endologix AFX(R) Endovascular AAA System; Endurant(R) Endovascular Stent Graft; Endurant(R) II AAA stent graft system; EXCLUDER(R) AAA Endoprosthesis; Express(R) (LD) Premounted Stent System; Express(R) Biliary SD Monorail(R) Premounted Stent System; Express(R) SD Renal Monorail(R) Premounted Stent System; FLAIR(R) Endovascular Stent Graft; Formula(tm) Balloon-Expandable Renal Stent System; GORE EXCLUDER(R) AAA Endoprosthesis; GORE TAG(R) Thoracic Endoprosthesis; GORE(R) VIABAHN(R) Endoprosthesis; GORE(R) VIABIL(R) Biliary Endoprosthesis; Herculink (RX) Elite Renal Stent System; Innova(tm) stent; LifeStent(R) (Flexstar)(XL) Vascular Stent System; Medtronic Endurant(R) II AAA stent graft system; Micro-Driver stent (RX) (OTW); MULTI-LINK (VISION)(MINI-VISION)(ULTRA) Coronary Stent System; Omnilink Elite Vascular Balloon Expandable Stent System; Protege(R) RX Carotid Stent System; Stent, intraluminal (cardiovascular)(gastrointestinal)(hepatobiliary)(urinary); Talent(R) Converter; Talent(R) Occluder; Talent(R) Stent Graft (abdominal)(thoracic); Therapeutic occlusion coil(s); Ultraflex(tm) Precision Colonic Stent System; Valiant Thoracic Stent Graft; WALLSTENT(R) Endoprosthesis; Xact Carotid Stent System; Zenith AAA Endovascular Graft; Zenith Flex(R) AAA Endovascular Graft; Zenith TX2(R) TAA Endovascular Graft; Zenith(R) Renu(tm) AAA Ancillary Graft

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 66.39Other bilateral destruction or occlusion of fallopian tubesapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0UL73DZ

Is 0UL73DZ a valid ICD-10-PCS code for 2027?

Yes. 0UL73DZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0UL73DZ an O.R. procedure?

Yes. 0UL73DZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0UL73DZ group to?

Depending on the principal diagnosis, 0UL73DZ can group to MS-DRG 744, MS-DRG 745, MS-DRG 783, MS-DRG 784, MS-DRG 785 and MS-DRG 796.

What is the ICD-9 procedure code for 0UL73DZ?

The CMS GEMs map 0UL73DZ to ICD-9-CM 66.39 (Other bilateral destruction or occlusion of fallopian tubes).