Skip to content
Dx

ICD-10-PCS 2027 procedure code

0UU67JZSupplement Left Fallopian Tube with Synthetic Substitute, Via Natural or Artificial Opening

✓ Valid for 2027O.R. procedureFemale only

Short description: Supplement Left Fallopian Tube with Synth Sub, Via Opening

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0UU67JZ

0UU67JZ is the ICD-10-PCS code for a supplement procedure on the left fallopian tube using a via natural or artificial opening approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.

In plain terms, this corresponds to implantation or replacement of prosthesis of fallopian tube, the ICD-9-CM procedure title it maps to (66.93).

For a different body part, codes include 0UU57JZ (right fallopian tube), 0UU77JZ (bilateral fallopian tubes), 0UUF7JZ (cul-de-sac), 0UUG7JZ (vagina) and 0UUK7JZ (hymen).

The same procedure with a different approach is coded 0UU60JZ (open), 0UU64JZ (percutaneous endoscopic) and 0UU68JZ (via natural or artificial opening endoscopic).

With a different device, use 0UU677Z (autologous tissue substitute) and 0UU67KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 731 (Uterine and Adnexa Procedures for Malignancy with MCC), DRG 732 (Uterine and Adnexa Procedures for Malignancy with CC), DRG 733 (Uterine and Adnexa Procedures for Malignancy without CC/MCC), DRG 742 (Uterine and Adnexa Procedures for Non-Malignancy with CC/MCC) and DRG 743 (Uterine and Adnexa Procedures for Non-Malignancy without CC/MCC), under the surgical categories “Uterine and Adnexa Procedures for Malignancy” and “Uterine and Adnexa Procedures for Non-Malignancy”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
UFemale Reproductive System
3. Operation
USupplement

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part

Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement

4. Body Part
6Fallopian Tube, Left

Includes: Oviduct; Salpinx; Uterine tube

5. Approach
7Via Natural or Artificial Opening

Entry of instrumentation through a natural or artificial external opening to reach the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 13 · Diseases and Disorders of the Female Reproductive System · Uterine and Adnexa Procedures for Non-Malignancy

ICD-9-CM equivalent

Converter →
  • 66.93Implantation or replacement of prosthesis of fallopian tubeapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0UU67JZ

Is 0UU67JZ a valid ICD-10-PCS code for 2027?

Yes. 0UU67JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0UU67JZ an O.R. procedure?

Yes. 0UU67JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0UU67JZ group to?

Depending on the principal diagnosis, 0UU67JZ can group to MS-DRG 731, MS-DRG 732, MS-DRG 733, MS-DRG 742 and MS-DRG 743.

What is the ICD-9 procedure code for 0UU67JZ?

The CMS GEMs map 0UU67JZ to ICD-9-CM 66.93 (Implantation or replacement of prosthesis of fallopian tube).