Skip to content
Dx

ICD-10-PCS 2027 procedure code

0UW83CZRevision of Extraluminal Device in Fallopian Tube, Percutaneous Approach

✓ Valid for 2027O.R. procedureFemale only

Short description: Revision of Extralum Dev in Fallopian Tube, Perc Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0UW83CZ

0UW83CZ is the ICD-10-PCS code for a revision procedure on the fallopian tube using a percutaneous approach with extraluminal device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Salpingotomy, the ICD-9-CM procedure title it maps to (66.01).

For a different body part, codes include 0UWD3CZ (uterus and cervix).

The same procedure with a different approach is coded 0UW80CZ (open), 0UW84CZ (percutaneous endoscopic), 0UW87CZ (via natural or artificial opening), 0UW88CZ (via natural or artificial opening endoscopic) and 0UW8XCZ (external).

With a different device, use 0UW830Z (drainage device), 0UW833Z (infusion device), 0UW837Z (autologous tissue substitute), 0UW83DZ (intraluminal device), 0UW83JZ (synthetic substitute), 0UW83KZ (nonautologous tissue substitute) and 1 more.

It is an operating-room procedure in the MS-DRG logic for DRG 731 (Uterine and Adnexa Procedures for Malignancy with MCC), DRG 732 (Uterine and Adnexa Procedures for Malignancy with CC), DRG 733 (Uterine and Adnexa Procedures for Malignancy without CC/MCC), DRG 742 (Uterine and Adnexa Procedures for Non-Malignancy with CC/MCC) and DRG 743 (Uterine and Adnexa Procedures for Non-Malignancy without CC/MCC), under the surgical categories “Uterine and Adnexa Procedures for Malignancy” and “Uterine and Adnexa Procedures for Non-Malignancy”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
UFemale Reproductive System
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
8Fallopian Tube
5. Approach
3Percutaneous

Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure

6. Device
CExtraluminal Device

Includes: AtriClip LAA Exclusion System; LAP-BAND(R) adjustable gastric banding system; REALIZE(R) Adjustable Gastric Band

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

MDC 13 · Diseases and Disorders of the Female Reproductive System · Uterine and Adnexa Procedures for Non-Malignancy

ICD-9-CM equivalent

Converter →
  • 66.01Salpingotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0UW83CZ

Is 0UW83CZ a valid ICD-10-PCS code for 2027?

Yes. 0UW83CZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0UW83CZ an O.R. procedure?

Yes. 0UW83CZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0UW83CZ group to?

Depending on the principal diagnosis, 0UW83CZ can group to MS-DRG 731, MS-DRG 732, MS-DRG 733, MS-DRG 742 and MS-DRG 743.

What is the ICD-9 procedure code for 0UW83CZ?

The CMS GEMs map 0UW83CZ to ICD-9-CM 66.01 (Salpingotomy).