Skip to content
Dx

ICD-10-PCS 2027 procedure code

0UWD07ZRevision of Autologous Tissue Substitute in Uterus and Cervix, Open Approach

✓ Valid for 2027O.R. procedureFemale only

Short description: Revision of Autol Sub in Uterus & Cervix, Open Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0UWD07Z

0UWD07Z is the ICD-10-PCS code for a revision procedure on the uterus and cervix using an open approach with autologous tissue substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.

In plain terms, this corresponds to Hysterotomy and incision of cervix, the ICD-9-CM procedure titles it maps to (68.0 and 69.95).

For a different body part, codes include 0UW807Z (fallopian tube), 0UWH07Z (vagina and cul-de-sac) and 0UWM07Z (vulva).

The same procedure with a different approach is coded 0UWD37Z (percutaneous), 0UWD47Z (percutaneous endoscopic), 0UWD77Z (via natural or artificial opening), 0UWD87Z (via natural or artificial opening endoscopic) and 0UWDX7Z (external).

With a different device, use 0UWD00Z (drainage device), 0UWD01Z (radioactive element), 0UWD03Z (infusion device), 0UWD0CZ (extraluminal device), 0UWD0DZ (intraluminal device), 0UWD0HZ (contraceptive device) and 3 more.

It is an operating-room procedure in the MS-DRG logic for DRG 731 (Uterine and Adnexa Procedures for Malignancy with MCC), DRG 732 (Uterine and Adnexa Procedures for Malignancy with CC), DRG 733 (Uterine and Adnexa Procedures for Malignancy without CC/MCC), DRG 742 (Uterine and Adnexa Procedures for Non-Malignancy with CC/MCC), DRG 743 (Uterine and Adnexa Procedures for Non-Malignancy without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Uterine and Adnexa Procedures for Malignancy”, “Uterine and Adnexa Procedures for Non-Malignancy”, “Other O.R. Procedures for Injuries” and 1 more.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
UFemale Reproductive System
3. Operation
WRevision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin

Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis

4. Body Part
DUterus and Cervix
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
7Autologous Tissue Substitute

Includes: Autograft; Cultured epidermal cell autograft; Epicel(R) cultured epidermal autograft

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 68.0Hysterotomyapproximate
  • 69.95Incision of cervixapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0UWD07Z

Is 0UWD07Z a valid ICD-10-PCS code for 2027?

Yes. 0UWD07Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0UWD07Z an O.R. procedure?

Yes. 0UWD07Z is an O.R. procedure in MS-DRG v44.0.

What DRG does 0UWD07Z group to?

Depending on the principal diagnosis, 0UWD07Z can group to MS-DRG 731, MS-DRG 732, MS-DRG 733, MS-DRG 742, MS-DRG 743 and MS-DRG 907.

What is the ICD-9 procedure code for 0UWD07Z?

The CMS GEMs map 0UWD07Z to ICD-9-CM 68.0 (Hysterotomy) and 69.95 (Incision of cervix).