ICD-10-PCS 2027 procedure code
0UWD3JZRevision of Synthetic Substitute in Uterus and Cervix, Percutaneous Approach
Short description: Revision of Synth Sub in Uterus & Cervix, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0UWD3JZ
0UWD3JZ is the ICD-10-PCS code for a revision procedure on the uterus and cervix using a percutaneous approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to Hysterotomy and incision of cervix, the ICD-9-CM procedure titles it maps to (68.0 and 69.95).
For a different body part, codes include 0UW83JZ (fallopian tube) and 0UWH3JZ (vagina and cul-de-sac).
The same procedure with a different approach is coded 0UWD0JZ (open), 0UWD4JZ (percutaneous endoscopic), 0UWD7JZ (via natural or artificial opening), 0UWD8JZ (via natural or artificial opening endoscopic) and 0UWDXJZ (external).
With a different device, use 0UWD30Z (drainage device), 0UWD31Z (radioactive element), 0UWD33Z (infusion device), 0UWD37Z (autologous tissue substitute), 0UWD3CZ (extraluminal device), 0UWD3DZ (intraluminal device) and 3 more.
It is an operating-room procedure in the MS-DRG logic for DRG 731 (Uterine and Adnexa Procedures for Malignancy with MCC), DRG 732 (Uterine and Adnexa Procedures for Malignancy with CC), DRG 733 (Uterine and Adnexa Procedures for Malignancy without CC/MCC), DRG 742 (Uterine and Adnexa Procedures for Non-Malignancy with CC/MCC), DRG 743 (Uterine and Adnexa Procedures for Non-Malignancy without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Uterine and Adnexa Procedures for Malignancy”, “Uterine and Adnexa Procedures for Non-Malignancy”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- UFemale Reproductive System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- DUterus and Cervix
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 13 · Diseases and Disorders of the Female Reproductive System · Uterine and Adnexa Procedures for Malignancy
MDC 13 · Diseases and Disorders of the Female Reproductive System · Uterine and Adnexa Procedures for Non-Malignancy
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0UWD3JZ
Is 0UWD3JZ a valid ICD-10-PCS code for 2027?
- Yes. 0UWD3JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0UWD3JZ an O.R. procedure?
- Yes. 0UWD3JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0UWD3JZ group to?
- Depending on the principal diagnosis, 0UWD3JZ can group to MS-DRG 731, MS-DRG 732, MS-DRG 733, MS-DRG 742, MS-DRG 743 and MS-DRG 907.
What is the ICD-9 procedure code for 0UWD3JZ?
- The CMS GEMs map 0UWD3JZ to ICD-9-CM 68.0 (Hysterotomy) and 69.95 (Incision of cervix).