Skip to content
Dx

ICD-10-PCS 2027 procedure code

0VU30JZSupplement Bilateral Seminal Vesicles with Synthetic Substitute, Open Approach

✓ Valid for 2027O.R. procedureMale only

Short description: Supplement Bi Seminal Vesicle with Synth Sub, Open Approach

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0VU30JZ

0VU30JZ is the ICD-10-PCS code for a supplement procedure on the bilateral seminal vesicles using an open approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.

In plain terms, this corresponds to other operations on seminal vesicles, the ICD-9-CM procedure title it maps to (60.79).

For a different body part, codes include 0VU10JZ (right seminal vesicle), 0VU20JZ (left seminal vesicle), 0VU50JZ (scrotum), 0VU60JZ (right tunica vaginalis), 0VU70JZ (left tunica vaginalis), 0VU90JZ (right testis) and 13 more.

The same procedure with a different approach is coded 0VU34JZ (percutaneous endoscopic) and 0VU38JZ (via natural or artificial opening endoscopic).

With a different device, use 0VU307Z (autologous tissue substitute) and 0VU30KZ (nonautologous tissue substitute).

It is an operating-room procedure in the MS-DRG logic for DRG 715 (Male Reproductive System and Other O.R. Procedures for Malignancy with CC/MCC), DRG 716 (Male Reproductive System and Other O.R. Procedures for Malignancy without CC/MCC), DRG 717 (Other Male Reproductive System O.R. Procedures with CC/MCC) and DRG 718 (Other Male Reproductive System O.R. Procedures without CC/MCC), under the surgical categories “” and “Other Male Reproductive System O.R. Procedures”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
VMale Reproductive System
3. Operation
USupplement

Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part

The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part

Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement

4. Body Part
3Seminal Vesicles, Bilateral
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
JSynthetic Substitute

Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 60.79Other operations on seminal vesiclesapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0VU30JZ

Is 0VU30JZ a valid ICD-10-PCS code for 2027?

Yes. 0VU30JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0VU30JZ an O.R. procedure?

Yes. 0VU30JZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0VU30JZ group to?

Depending on the principal diagnosis, 0VU30JZ can group to MS-DRG 715, MS-DRG 716, MS-DRG 717 and MS-DRG 718.

What is the ICD-9 procedure code for 0VU30JZ?

The CMS GEMs map 0VU30JZ to ICD-9-CM 60.79 (Other operations on seminal vesicles).