ICD-10-PCS 2027 procedure code
0VW44JZRevision of Synthetic Substitute in Prostate and Seminal Vesicles, Percutaneous Endoscopic Approach
Short description: Revise Synth Sub in Prostate/Seminal Ves, Perc Endo
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0VW44JZ
0VW44JZ is the ICD-10-PCS code for a revision procedure on the prostate and seminal vesicles using a percutaneous endoscopic approach with synthetic substitute. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to incision of prostate and incision of seminal vesicle, the ICD-9-CM procedure titles it maps to (60.0 and 60.72).
For a different body part, codes include 0VW84JZ (scrotum and tunica vaginalis), 0VWD4JZ (testis), 0VWM4JZ (epididymis and spermatic cord), 0VWR4JZ (vas deferens) and 0VWS4JZ (penis).
The same procedure with a different approach is coded 0VW40JZ (open), 0VW43JZ (percutaneous), 0VW47JZ (via natural or artificial opening), 0VW48JZ (via natural or artificial opening endoscopic) and 0VW4XJZ (external).
With a different device, use 0VW440Z (drainage device), 0VW443Z (infusion device), 0VW447Z (autologous tissue substitute), 0VW44KZ (nonautologous tissue substitute) and 0VW44YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 715 (Male Reproductive System and Other O.R. Procedures for Malignancy with CC/MCC), DRG 716 (Male Reproductive System and Other O.R. Procedures for Malignancy without CC/MCC), DRG 717 (Other Male Reproductive System O.R. Procedures with CC/MCC) and DRG 718 (Other Male Reproductive System O.R. Procedures without CC/MCC), under the surgical categories “” and “Other Male Reproductive System O.R. Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- VMale Reproductive System
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- 4Prostate and Seminal Vesicles
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 12 · Diseases and Disorders of the Male Reproductive System
MDC 12 · Diseases and Disorders of the Male Reproductive System · Other Male Reproductive System O.R. Procedures
ICD-9-CM equivalent
Converter →From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0VW44JZ
Is 0VW44JZ a valid ICD-10-PCS code for 2027?
- Yes. 0VW44JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0VW44JZ an O.R. procedure?
- Yes. 0VW44JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 0VW44JZ group to?
- Depending on the principal diagnosis, 0VW44JZ can group to MS-DRG 715, MS-DRG 716, MS-DRG 717 and MS-DRG 718.
What is the ICD-9 procedure code for 0VW44JZ?
- The CMS GEMs map 0VW44JZ to ICD-9-CM 60.0 (Incision of prostate) and 60.72 (Incision of seminal vesicle).