Skip to content
Dx

ICD-10-PCS 2027 procedure code

0WH10YZInsertion of Other Device into Cranial Cavity, Open Approach

✓ Valid for 2027O.R. procedure

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 0WH10YZ

0WH10YZ is the ICD-10-PCS code for a insertion procedure on the cranial cavity using an open approach with other device. In ICD-10-PCS, insertion means putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part.

In plain terms, this corresponds to other craniotomy, the ICD-9-CM procedure title it maps to (01.24).

For a different body part, codes include 0WH00YZ (head), 0WH20YZ (face), 0WH30YZ (oral cavity and throat), 0WH40YZ (upper jaw), 0WH50YZ (lower jaw), 0WH60YZ (neck) and 16 more.

The same procedure with a different approach is coded 0WH13YZ (percutaneous) and 0WH14YZ (percutaneous endoscopic).

With a different device, use 0WH101Z (radioactive element) and 0WH103Z (infusion device).

It is an operating-room procedure in the MS-DRG logic for DRG 023 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis with MCC or Antineoplastic Implant or Epilepsy with Neurostimulator), DRG 024 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis without MCC), DRG 025 (Craniotomy and Endovascular Intracranial Procedures with MCC), DRG 026 (Craniotomy and Endovascular Intracranial Procedures with CC) and DRG 027 (Craniotomy and Endovascular Intracranial Procedures without CC/MCC), under the surgical categories “Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis” and “Craniotomy and endovascular intracranial procedures”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
0Medical and Surgical
2. Body System
WAnatomical Regions, General
3. Operation
HInsertion

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

Includes: Insertion of radioactive implant, insertion of central venous catheter

4. Body Part
1Cranial Cavity
5. Approach
0Open

Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure

6. Device
YOther Device

Includes: Alfapump(R) system

7. Qualifier
ZNo Qualifier

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 01.24Other craniotomyapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 0WH10YZ

Is 0WH10YZ a valid ICD-10-PCS code for 2027?

Yes. 0WH10YZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 0WH10YZ an O.R. procedure?

Yes. 0WH10YZ is an O.R. procedure in MS-DRG v44.0.

What DRG does 0WH10YZ group to?

Depending on the principal diagnosis, 0WH10YZ can group to MS-DRG 023, MS-DRG 024, MS-DRG 025, MS-DRG 026 and MS-DRG 027.

What is the ICD-9 procedure code for 0WH10YZ?

The CMS GEMs map 0WH10YZ to ICD-9-CM 01.24 (Other craniotomy).