ICD-10-PCS 2027 procedure code
0WWF41ZRevision of Radioactive Element in Abdominal Wall, Percutaneous Endoscopic Approach
Short description: Revision of Radioact Elem in Abd Wall, Perc Endo Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0WWF41Z
0WWF41Z is the ICD-10-PCS code for a revision procedure on the abdominal wall using a percutaneous endoscopic approach with radioactive element. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to incision of abdominal wall, the ICD-9-CM procedure title it maps to (54.0).
For a different body part, codes include 0WW041Z (head), 0WW141Z (cranial cavity), 0WW241Z (face), 0WW441Z (upper jaw), 0WW541Z (lower jaw), 0WW641Z (neck) and 15 more.
The same procedure with a different approach is coded 0WWF01Z (open), 0WWF31Z (percutaneous) and 0WWFX1Z (external).
With a different device, use 0WWF40Z (drainage device), 0WWF43Z (infusion device), 0WWF47Z (autologous tissue substitute), 0WWF4JZ (synthetic substitute), 0WWF4KZ (nonautologous tissue substitute) and 0WWF4YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 356 (Other Digestive System O.R. Procedures with MCC), DRG 357 (Other Digestive System O.R. Procedures with CC), DRG 358 (Other Digestive System O.R. Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Other Digestive System O.R. Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- WAnatomical Regions, General
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- FAbdominal Wall
- 5. Approach
- 4Percutaneous Endoscopic
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach and visualize the site of the procedure
- 6. Device
- 1Radioactive Element
Includes: Brachytherapy seeds; CivaSheet(R)
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 06 · Diseases and Disorders of the Digestive System · Other Digestive System O.R. Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 54.0Incision of abdominal wallapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0WWF41Z
Is 0WWF41Z a valid ICD-10-PCS code for 2027?
- Yes. 0WWF41Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0WWF41Z an O.R. procedure?
- Yes. 0WWF41Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 0WWF41Z group to?
- Depending on the principal diagnosis, 0WWF41Z can group to MS-DRG 356, MS-DRG 357, MS-DRG 358, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 0WWF41Z?
- The CMS GEMs map 0WWF41Z to ICD-9-CM 54.0 (Incision of abdominal wall).