ICD-10-PCS 2027 procedure code
0YWB33ZRevision of Infusion Device in Left Lower Extremity, Percutaneous Approach
Short description: Revision of Infusion Device in L Low Extrem, Perc Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 0YWB33Z
0YWB33Z is the ICD-10-PCS code for a revision procedure on the left lower extremity using a percutaneous approach with infusion device. In ICD-10-PCS, revision means correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device.
In plain terms, this corresponds to other incision of skin and subcutaneous tissue, the ICD-9-CM procedure title it maps to (86.09).
For a different body part, codes include 0YW933Z (right lower extremity).
The same procedure with a different approach is coded 0YWB03Z (open), 0YWB43Z (percutaneous endoscopic) and 0YWBX3Z (external).
With a different device, use 0YWB30Z (drainage device), 0YWB37Z (autologous tissue substitute), 0YWB3JZ (synthetic substitute), 0YWB3KZ (nonautologous tissue substitute) and 0YWB3YZ (other device).
It is a non-O.R. procedure that is part of the MS-DRG logic for DRG 579 (Other Skin, Subcutaneous Tissue and Breast Procedures with MCC), DRG 580 (Other Skin, Subcutaneous Tissue and Breast Procedures with CC) and DRG 581 (Other Skin, Subcutaneous Tissue and Breast Procedures without CC/MCC), under the surgical category “Other Skin, Subcutaneous Tissue and Breast Procedures”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- YAnatomical Regions, Lower Extremities
- 3. Operation
- WRevision
Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device
Revision can include correcting a malfunctioning or displaced device by taking out or putting in components of the device such as a screw or pin
Includes: Adjustment of position of pacemaker lead, recementing of hip prosthesis
- 4. Body Part
- BLower Extremity, Left
- 5. Approach
- 3Percutaneous
Entry, by puncture or minor incision, of instrumentation through the skin or mucous membrane and any other body layers necessary to reach the site of the procedure
- 6. Device
- 3Infusion Device
Includes: Ascenda Intrathecal Catheter; InDura, intrathecal catheter (1P) (spinal); Non-tunneled central venous catheter; Peripherally inserted central catheter (PICC); Tunneled spinal (intrathecal) catheter
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 09 · Diseases and Disorders of the Skin, Subcutaneous Tissue and Breast · Other Skin, Subcutaneous Tissue and Breast Procedures
ICD-9-CM equivalent
Converter →- 86.09Other incision of skin and subcutaneous tissueapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 0YWB33Z
Is 0YWB33Z a valid ICD-10-PCS code for 2027?
- Yes. 0YWB33Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 0YWB33Z an O.R. procedure?
- No. 0YWB33Z is designated non-O.R. in MS-DRG v44.0.
What DRG does 0YWB33Z group to?
- Depending on the principal diagnosis, 0YWB33Z can group to MS-DRG 579, MS-DRG 580 and MS-DRG 581.
What is the ICD-9 procedure code for 0YWB33Z?
- The CMS GEMs map 0YWB33Z to ICD-9-CM 86.09 (Other incision of skin and subcutaneous tissue).