Skip to content
Dx

ICD-10-PCS 2027 procedure code

5A02110Assistance with Cardiac Output using Balloon Pump, Intermittent

✓ Valid for 2027O.R. procedure

Short description: Assist with Cardiac Output using Balloon Pump, Intermittent

Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data

About 5A02110

5A02110 is the ICD-10-PCS code for a assistance procedure on the cardiac using an intermittent approach with output (qualifier: balloon pump). In ICD-10-PCS, assistance means taking over a portion of a physiological function by extracorporeal means.

In plain terms, this corresponds to implant of pulsation balloon, the ICD-9-CM procedure title it maps to (37.61).

The same procedure with a different approach is coded 5A02210 (continuous).

It is an operating-room procedure in the MS-DRG logic for DRG 270 (Other Major Cardiovascular Procedures with MCC), DRG 271 (Other Major Cardiovascular Procedures with CC) and DRG 272 (Other Major Cardiovascular Procedures without CC/MCC), under the surgical category “Other Major Cardiovascular Procedures”.

It has been valid since ICD-10-PCS took effect on October 1, 2015.

What each character means

1. Section
5Extracorporeal or Systemic Assistance and Performance
2. Body System
APhysiological Systems
3. Operation
0Assistance

Taking over a portion of a physiological function by extracorporeal means

4. Body System
2Cardiac
5. Duration
1Intermittent
6. Function
1Output
7. Qualifier
0Balloon Pump

Other versions of this procedure

MS-DRG v44.0 grouping

All DRGs →

Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.

ICD-9-CM equivalent

Converter →
  • 37.61Implant of pulsation balloonapproximate

From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.

Code history

  1. 2016
  2. 2017
  3. 2018
  4. 2019
  5. 2020
  6. 2021
  7. 2022
  8. 2023
  9. 2024
  10. 2025
  11. 2026
  12. 2027
  • FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
  • No changes since FY2016.

Common questions about 5A02110

Is 5A02110 a valid ICD-10-PCS code for 2027?

Yes. 5A02110 is valid for inpatient procedures from October 1, 2026 through September 30, 2027.

Is 5A02110 an O.R. procedure?

Yes. 5A02110 is an O.R. procedure in MS-DRG v44.0.

What DRG does 5A02110 group to?

Depending on the principal diagnosis, 5A02110 can group to MS-DRG 270, MS-DRG 271 and MS-DRG 272.

What is the ICD-9 procedure code for 5A02110?

The CMS GEMs map 5A02110 to ICD-9-CM 37.61 (Implant of pulsation balloon).