ICD-10-PCS table F13
Hearing Assessment, Diagnostic Audiology
Hearing Assessment: Measurement of hearing and related functions
Table rows
4 · Body System / Region
- ZNone
5 · Type Qualifier
- 0Hearing Screening
6 · Equipment
- 0Occupational Hearing
- 1Audiometer
- 2Sound Field / Booth
- 3Tympanometer
- 8Vestibular / Balance
- 9Cochlear Implant
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- 1Pure Tone Audiometry, Air
- 2Pure Tone Audiometry, Air and Bone
6 · Equipment
- 0Occupational Hearing
- 1Audiometer
- 2Sound Field / Booth
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- 3Bekesy Audiometry
- 6Visual Reinforcement Audiometry
- 9Short Increment Sensitivity Index
- BStenger
- CPure Tone Stenger
6 · Equipment
- 1Audiometer
- 2Sound Field / Booth
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- 4Conditioned Play Audiometry
- 5Select Picture Audiometry
6 · Equipment
- 1Audiometer
- 2Sound Field / Booth
- KAudiovisual
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- 7Alternate Binaural or Monaural Loudness Balance
6 · Equipment
- 1Audiometer
- KAudiovisual
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- 8Tone Decay
- DTympanometry
- FEustachian Tube Function
- GAcoustic Reflex Patterns
- HAcoustic Reflex Threshold
- JAcoustic Reflex Decay
6 · Equipment
- 3Tympanometer
- 4Electroacoustic Immitance / Acoustic Reflex
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- KElectrocochleography
- LAuditory Evoked Potentials
6 · Equipment
- 7Electrophysiologic
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- MEvoked Otoacoustic Emissions, Screening
- NEvoked Otoacoustic Emissions, Diagnostic
6 · Equipment
- 6Otoacoustic Emission (OAE)
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- PAural Rehabilitation Status
6 · Equipment
- 1Audiometer
- 2Sound Field / Booth
- 4Electroacoustic Immitance / Acoustic Reflex
- 9Cochlear Implant
- KAudiovisual
- LAssistive Listening
- PComputer
- ZNone
7 · Qualifier
- ZNone
4 · Body System / Region
- ZNone
5 · Type Qualifier
- QAuditory Processing
6 · Equipment
- KAudiovisual
- PComputer
- YOther Equipment
- ZNone
7 · Qualifier
- ZNone
All 79 valid codes in F13
- F13Z00ZHearing Screening Assessment using Occupational Hearing Equipment
- F13Z01ZHearing Screening Assessment using Audiometer
- F13Z02ZHearing Screening Assessment using Sound Field / Booth
- F13Z03ZHearing Screening Assessment using Tympanometer
- F13Z08ZHearing Screening Assessment using Vestibular / Balance Equipment
- F13Z09ZHearing Screening Assessment using Cochlear Implant Equipment
- F13Z0ZZHearing Screening Assessment
- F13Z10ZPure Tone Audiometry, Air Assessment using Occupational Hearing Equipment
- F13Z11ZPure Tone Audiometry, Air Assessment using Audiometer
- F13Z12ZPure Tone Audiometry, Air Assessment using Sound Field / Booth
- F13Z1ZZPure Tone Audiometry, Air Assessment
- F13Z20ZPure Tone Audiometry, Air and Bone Assessment using Occupational Hearing Equipment
- F13Z21ZPure Tone Audiometry, Air and Bone Assessment using Audiometer
- F13Z22ZPure Tone Audiometry, Air and Bone Assessment using Sound Field / Booth
- F13Z2ZZPure Tone Audiometry, Air and Bone Assessment
- F13Z31ZBekesy Audiometry Assessment using Audiometer
- F13Z32ZBekesy Audiometry Assessment using Sound Field / Booth
- F13Z3ZZBekesy Audiometry Assessment
- F13Z41ZConditioned Play Audiometry Assessment using Audiometer
- F13Z42ZConditioned Play Audiometry Assessment using Sound Field / Booth
- F13Z4KZConditioned Play Audiometry Assessment using Audiovisual Equipment
- F13Z4ZZConditioned Play Audiometry Assessment
- F13Z51ZSelect Picture Audiometry Assessment using Audiometer
- F13Z52ZSelect Picture Audiometry Assessment using Sound Field / Booth
- F13Z5KZSelect Picture Audiometry Assessment using Audiovisual Equipment
- F13Z5ZZSelect Picture Audiometry Assessment
- F13Z61ZVisual Reinforcement Audiometry Assessment using Audiometer
- F13Z62ZVisual Reinforcement Audiometry Assessment using Sound Field / Booth
- F13Z6ZZVisual Reinforcement Audiometry Assessment
- F13Z71ZAlternate Binaural or Monaural Loudness Balance Assessment using Audiometer
- F13Z7KZAlternate Binaural or Monaural Loudness Balance Assessment using Audiovisual Equipment
- F13Z7ZZAlternate Binaural or Monaural Loudness Balance Assessment
- F13Z83ZTone Decay Assessment using Tympanometer
- F13Z84ZTone Decay Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13Z8ZZTone Decay Assessment
- F13Z91ZShort Increment Sensitivity Index Assessment using Audiometer
- F13Z92ZShort Increment Sensitivity Index Assessment using Sound Field / Booth
- F13Z9ZZShort Increment Sensitivity Index Assessment
- F13ZB1ZStenger Assessment using Audiometer
- F13ZB2ZStenger Assessment using Sound Field / Booth
- F13ZBZZStenger Assessment
- F13ZC1ZPure Tone Stenger Assessment using Audiometer
- F13ZC2ZPure Tone Stenger Assessment using Sound Field / Booth
- F13ZCZZPure Tone Stenger Assessment
- F13ZD3ZTympanometry Assessment using Tympanometer
- F13ZD4ZTympanometry Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13ZDZZTympanometry Assessment
- F13ZF3ZEustachian Tube Function Assessment using Tympanometer
- F13ZF4ZEustachian Tube Function Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13ZFZZEustachian Tube Function Assessment
- F13ZG3ZAcoustic Reflex Patterns Assessment using Tympanometer
- F13ZG4ZAcoustic Reflex Patterns Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13ZGZZAcoustic Reflex Patterns Assessment
- F13ZH3ZAcoustic Reflex Threshold Assessment using Tympanometer
- F13ZH4ZAcoustic Reflex Threshold Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13ZHZZAcoustic Reflex Threshold Assessment
- F13ZJ3ZAcoustic Reflex Decay Assessment using Tympanometer
- F13ZJ4ZAcoustic Reflex Decay Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13ZJZZAcoustic Reflex Decay Assessment
- F13ZK7ZElectrocochleography Assessment using Electrophysiologic Equipment
- F13ZKZZElectrocochleography Assessment
- F13ZL7ZAuditory Evoked Potentials Assessment using Electrophysiologic Equipment
- F13ZLZZAuditory Evoked Potentials Assessment
- F13ZM6ZEvoked Otoacoustic Emissions, Screening Assessment using Otoacoustic Emission (OAE) Equipment
- F13ZMZZEvoked Otoacoustic Emissions, Screening Assessment
- F13ZN6ZEvoked Otoacoustic Emissions, Diagnostic Assessment using Otoacoustic Emission (OAE) Equipment
- F13ZNZZEvoked Otoacoustic Emissions, Diagnostic Assessment
- F13ZP1ZAural Rehabilitation Status Assessment using Audiometer
- F13ZP2ZAural Rehabilitation Status Assessment using Sound Field / Booth
- F13ZP4ZAural Rehabilitation Status Assessment using Electroacoustic Immitance / Acoustic Reflex Equipment
- F13ZP9ZAural Rehabilitation Status Assessment using Cochlear Implant Equipment
- F13ZPKZAural Rehabilitation Status Assessment using Audiovisual Equipment
- F13ZPLZAural Rehabilitation Status Assessment using Assistive Listening Equipment
- F13ZPPZAural Rehabilitation Status Assessment using Computer
- F13ZPZZAural Rehabilitation Status Assessment
- F13ZQKZAuditory Processing Assessment using Audiovisual Equipment
- F13ZQPZAuditory Processing Assessment using Computer
- F13ZQYZAuditory Processing Assessment using Other Equipment
- F13ZQZZAuditory Processing Assessment