ICD-10-PCS 2027 procedure code
00P003ZRemoval of Infusion Device from Brain, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 00P003Z
00P003Z is the ICD-10-PCS code for a removal procedure on the brain using an open approach with infusion device. In ICD-10-PCS, removal means taking out or off a device from a body part.
In plain terms, this corresponds to other incision of brain, the ICD-9-CM procedure title it maps to (01.39).
For a different body part, codes include 00P603Z (cerebral ventricle), 00PE03Z (cranial nerve), 00PU03Z (spinal canal) and 00PV03Z (spinal cord).
The same procedure with a different approach is coded 00P033Z (percutaneous), 00P043Z (percutaneous endoscopic) and 00P0X3Z (external).
With a different device, use 00P000Z (drainage device), 00P002Z (monitoring device), 00P007Z (autologous tissue substitute), 00P00JZ (synthetic substitute), 00P00KZ (nonautologous tissue substitute), 00P00MZ (neurostimulator lead) and 1 more.
It is an operating-room procedure in the MS-DRG logic for DRG 023 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis with MCC or Antineoplastic Implant or Epilepsy with Neurostimulator), DRG 024 (Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis without MCC), DRG 025 (Craniotomy and Endovascular Intracranial Procedures with MCC), DRG 026 (Craniotomy and Endovascular Intracranial Procedures with CC), DRG 027 (Craniotomy and Endovascular Intracranial Procedures without CC/MCC) and DRG 907 (Other O.R. Procedures for Injuries with MCC), under the surgical categories “Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis”, “Craniotomy and endovascular intracranial procedures”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 0Central Nervous System and Cranial Nerves
- 3. Operation
- PRemoval
Taking out or off a device from a body part
If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL
Includes: Drainage tube removal, cardiac pacemaker removal
- 4. Body Part
- 0Brain
Includes: Cerebrum; Corpus callosum; Encephalon
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- 3Infusion Device
Includes: Ascenda Intrathecal Catheter; InDura, intrathecal catheter (1P) (spinal); Non-tunneled central venous catheter; Peripherally inserted central catheter (PICC); Tunneled spinal (intrathecal) catheter
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis
MDC 01 · Diseases and Disorders of the Nervous System · Craniotomy and endovascular intracranial procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Craniotomy for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 01.39Other incision of brainapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 00P003Z
Is 00P003Z a valid ICD-10-PCS code for 2027?
- Yes. 00P003Z is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 00P003Z an O.R. procedure?
- Yes. 00P003Z is an O.R. procedure in MS-DRG v44.0.
What DRG does 00P003Z group to?
- Depending on the principal diagnosis, 00P003Z can group to MS-DRG 023, MS-DRG 024, MS-DRG 025, MS-DRG 026, MS-DRG 027 and MS-DRG 907.
What is the ICD-9 procedure code for 00P003Z?
- The CMS GEMs map 00P003Z to ICD-9-CM 01.39 (Other incision of brain).