ICD-10-PCS 2027 procedure code
00P60JZRemoval of Synthetic Substitute from Cerebral Ventricle, Open Approach
Short description: Removal of Synth Sub from Cereb Vent, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 00P60JZ
00P60JZ is the ICD-10-PCS code for a removal procedure on the cerebral ventricle using an open approach with synthetic substitute. In ICD-10-PCS, removal means taking out or off a device from a body part.
In plain terms, this corresponds to removal of ventricular shunt, the ICD-9-CM procedure title it maps to (02.43).
For a different body part, codes include 00P00JZ (brain), 00P20JZ (dura mater), 00PT0JZ (spinal meninges), 00PU0JZ (spinal canal) and 00PV0JZ (spinal cord).
The same procedure with a different approach is coded 00P63JZ (percutaneous) and 00P64JZ (percutaneous endoscopic).
With a different device, use 00P600Z (drainage device), 00P602Z (monitoring device), 00P603Z (infusion device), 00P60MZ (neurostimulator lead) and 00P60YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 031 (Ventricular Shunt Procedures with MCC), DRG 032 (Ventricular Shunt Procedures with CC), DRG 033 (Ventricular Shunt Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Ventricular Shunt Procedures”, “Other O.R. Procedures for Injuries” and “Other O.R. Procedures for Multiple Significant Trauma”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 0Central Nervous System and Cranial Nerves
- 3. Operation
- PRemoval
Taking out or off a device from a body part
If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL
Includes: Drainage tube removal, cardiac pacemaker removal
- 4. Body Part
- 6Cerebral Ventricle
Includes: Aqueduct of Sylvius; Cerebral aqueduct (Sylvius); Choroid plexus; Ependyma; Foramen of Monro (intraventricular); Fourth ventricle; Interventricular foramen (Monro); Left lateral ventricle; Right lateral ventricle; Third ventricle
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Ventricular Shunt Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 02.43Removal of ventricular shuntapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 00P60JZ
Is 00P60JZ a valid ICD-10-PCS code for 2027?
- Yes. 00P60JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 00P60JZ an O.R. procedure?
- Yes. 00P60JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 00P60JZ group to?
- Depending on the principal diagnosis, 00P60JZ can group to MS-DRG 031, MS-DRG 032, MS-DRG 033, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 00P60JZ?
- The CMS GEMs map 00P60JZ to ICD-9-CM 02.43 (Removal of ventricular shunt).