ICD-10-PCS 2027 procedure code
00PU0JZRemoval of Synthetic Substitute from Spinal Canal, Open Approach
Short description: Removal of Synth Sub from Spinal Canal, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 00PU0JZ
00PU0JZ is the ICD-10-PCS code for a removal procedure on the spinal canal using an open approach with synthetic substitute. In ICD-10-PCS, removal means taking out or off a device from a body part.
In plain terms, this corresponds to removal of spinal thecal shunt, the ICD-9-CM procedure title it maps to (03.98).
For a different body part, codes include 00P00JZ (brain), 00P20JZ (dura mater), 00P60JZ (cerebral ventricle), 00PT0JZ (spinal meninges) and 00PV0JZ (spinal cord).
The same procedure with a different approach is coded 00PU3JZ (percutaneous) and 00PU4JZ (percutaneous endoscopic).
With a different device, use 00PU00Z (drainage device), 00PU02Z (monitoring device), 00PU03Z (infusion device), 00PU0MZ (neurostimulator lead) and 00PU0YZ (other device).
It is an operating-room procedure in the MS-DRG logic for DRG 028 (Spinal Procedures with MCC), DRG 029 (Spinal Procedures with CC or Spinal Neurostimulators), DRG 030 (Spinal Procedures without CC/MCC), DRG 518 (Back and Neck Procedures Except Spinal Fusion with MCC or Disc Device or Neurostimulator), DRG 519 (Back and Neck Procedures Except Spinal Fusion with CC) and DRG 520 (Back and Neck Procedures Except Spinal Fusion without CC/MCC), under the surgical categories “Spinal Procedures”, “Back and Neck Procedures Except Spinal Fusion or Disc Device or Neurostimulator”, “Other O.R. Procedures for Injuries” and 1 more.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 0Central Nervous System and Cranial Nerves
- 3. Operation
- PRemoval
Taking out or off a device from a body part
If a device is taken out and a similar device put in without cutting or puncturing the skin or mucous membrane, the procedure is coded to the root operation CHANGE. Otherwise, the procedure for taking out a device is coded to the root operation REMOVAL
Includes: Drainage tube removal, cardiac pacemaker removal
- 4. Body Part
- USpinal Canal
Includes: Epidural space, spinal; Extradural space, spinal; Subarachnoid space, spinal; Subdural space, spinal; Vertebral canal
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 01 · Diseases and Disorders of the Nervous System · Spinal Procedures
MDC 08 · Diseases and Disorders of the Musculoskeletal System and Connective Tissue · Back and Neck Procedures Except Spinal Fusion or Disc Device or Neurostimulator
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
MDC 24 · Multiple Significant Trauma · Other O.R. Procedures for Multiple Significant Trauma
ICD-9-CM equivalent
Converter →- 03.98Removal of spinal thecal shuntapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 00PU0JZ
Is 00PU0JZ a valid ICD-10-PCS code for 2027?
- Yes. 00PU0JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 00PU0JZ an O.R. procedure?
- Yes. 00PU0JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 00PU0JZ group to?
- Depending on the principal diagnosis, 00PU0JZ can group to MS-DRG 028, MS-DRG 029, MS-DRG 030, MS-DRG 518, MS-DRG 519 and MS-DRG 520.
What is the ICD-9 procedure code for 00PU0JZ?
- The CMS GEMs map 00PU0JZ to ICD-9-CM 03.98 (Removal of spinal thecal shunt).