ICD-10-PCS 2027 procedure code
02UT0JZSupplement Left Pulmonary Vein with Synthetic Substitute, Open Approach
Short description: Supplement Left Pulmonary Vein with Synth Sub, Open Approach
Code unchanged since ICD-10-PCS took effect on October 1, 2015. Source: official FY2027 ICD-10-PCS release from CMS. Page updated September 29, 2026. About our data
About 02UT0JZ
02UT0JZ is the ICD-10-PCS code for a supplement procedure on the left pulmonary vein using an open approach with synthetic substitute. In ICD-10-PCS, supplement means putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part.
In plain terms, this corresponds to repair of blood vessel with synthetic patch graft, the ICD-9-CM procedure title it maps to (39.57).
For a different body part, codes include 02U00JZ (coronary artery, one artery), 02U10JZ (coronary artery, two arteries), 02U20JZ (coronary artery, three arteries), 02U30JZ (coronary artery, four or more arteries), 02U50JZ (atrial septum), 02U60JZ (right atrium) and 19 more.
The same procedure with a different approach is coded 02UT3JZ (percutaneous) and 02UT4JZ (percutaneous endoscopic).
With a different device, use 02UT07Z (autologous tissue substitute), 02UT08Z (zooplastic tissue) and 02UT0KZ (nonautologous tissue substitute).
It is an operating-room procedure in the MS-DRG logic for DRG 252 (Other Vascular Procedures with MCC), DRG 253 (Other Vascular Procedures with CC), DRG 254 (Other Vascular Procedures without CC/MCC), DRG 907 (Other O.R. Procedures for Injuries with MCC), DRG 908 (Other O.R. Procedures for Injuries with CC) and DRG 909 (Other O.R. Procedures for Injuries without CC/MCC), under the surgical categories “Other Vascular Procedures” and “Other O.R. Procedures for Injuries”.
It has been valid since ICD-10-PCS took effect on October 1, 2015.
What each character means
- 1. Section
- 0Medical and Surgical
- 2. Body System
- 2Heart and Great Vessels
- 3. Operation
- USupplement
Putting in or on biological or synthetic material that physically reinforces and/or augments the function of a portion of a body part
The biological material is non-living, or is living and from the same individual. The body part may have been previously replaced, and the Supplement procedure is performed to physically reinforce and/or augment the function of the replaced body part
Includes: Herniorrhaphy using mesh, mitral valve ring annuloplasty, put a new acetabular liner in a previous hip replacement
- 4. Body Part
- TPulmonary Vein, Left
Includes: Left inferior pulmonary vein; Left superior pulmonary vein
- 5. Approach
- 0Open
Cutting through the skin or mucous membrane and any other body layers necessary to expose the site of the procedure
- 6. Device
- JSynthetic Substitute
Includes: AbioCor(R) Total Replacement Heart; AMPLATZER(R) Muscular VSD Occluder; Annuloplasty ring; Bard(R) Composix(R) (E/X)(LP) mesh; Bard(R) Composix(R) Kugel(R) patch; Bard(R) Dulex(tm) mesh; Bard(R) Ventralex(tm) hernia patch; Barricaid(R) Annular Closure Device (ACD); BRYAN(R) Cervical Disc System; Corvia IASD(R); Ex-PRESS(tm) mini glaucoma shunt; Flexible Composite Mesh; GORE(R) ACUSEAL Vascular Graft; GORE(R) CARDIOFORM Septal Occluder; GORE(R) DUALMESH(R); GORE(R) PROPATEN(R) Vascular Graft; GORE(R) VIATORR(R) TIPS Endoprosthesis; Holter valve ventricular shunt; IASD(R) (InterAtrial Shunt Device), Corvia; InterAtrial Shunt Device IASD(R), Corvia; LimFlow(tm) Transcatheter Arterialization of the Deep Veins (TADV) System; MitraClip valve repair system; Nitinol framed polymer mesh; Open Pivot (mechanical) valve; Open Pivot Aortic Valve Graft (AVG); Partially absorbable mesh; PHYSIOMESH(tm) Flexible Composite Mesh; Polymethylmethacrylate (PMMA); Polypropylene mesh; PRESTIGE(R) Cervical Disc; PROCEED(tm) Ventral Patch; Prodisc-C; Prodisc-L; PROLENE Polypropylene Hernia System (PHS); Rebound HRD(R) (Hernia Repair Device); SynCardia Total Artificial Heart; Total artificial (replacement) heart; ULTRAPRO Hernia System (UHS); ULTRAPRO Partially Absorbable Lightweight Mesh; ULTRAPRO Plug; V-Wave Interatrial Shunt System; Ventrio(tm) Hernia Patch; Zimmer(R) NexGen(R) LPS Mobile Bearing Knee; Zimmer(R) NexGen(R) LPS-Flex Mobile Knee
- 7. Qualifier
- ZNo Qualifier
Other versions of this procedure
Different body part
- 02U00JZCoronary Artery, One Artery
- 02U10JZCoronary Artery, Two Arteries
- 02U20JZCoronary Artery, Three Arteries
- 02U30JZCoronary Artery, Four or More Arteries
- 02U50JZAtrial Septum
- 02U60JZAtrium, Right
- 02U70JZAtrium, Left
- 02U90JZChordae Tendineae
- 02UA0JZHeart
- 02UD0JZPapillary Muscle
- 02UF0JZAortic Valve
- 02UG0JZMitral Valve
Different approach
MS-DRG v44.0 grouping
All DRGs →Surgical MS-DRGs this procedure can group to, depending on the principal diagnosis's MDC.
MDC 05 · Diseases and Disorders of the Circulatory System · Other Vascular Procedures
MDC 21 · Injuries, Poisonings and Toxic Effects of Drugs · Other O.R. Procedures for Injuries
ICD-9-CM equivalent
Converter →- 39.57Repair of blood vessel with synthetic patch graftapproximate
From the CMS 2018 General Equivalence Mappings (GEMs), the final GEMs release.
Code history
- 2016
- 2017
- 2018
- 2019
- 2020
- 2021
- 2022
- 2023
- 2024
- 2025
- 2026
- 2027
- FY2016 (effective 10/1/2015): Added (first year of ICD-10-CM)
- No changes since FY2016.
Common questions about 02UT0JZ
Is 02UT0JZ a valid ICD-10-PCS code for 2027?
- Yes. 02UT0JZ is valid for inpatient procedures from October 1, 2026 through September 30, 2027.
Is 02UT0JZ an O.R. procedure?
- Yes. 02UT0JZ is an O.R. procedure in MS-DRG v44.0.
What DRG does 02UT0JZ group to?
- Depending on the principal diagnosis, 02UT0JZ can group to MS-DRG 252, MS-DRG 253, MS-DRG 254, MS-DRG 907, MS-DRG 908 and MS-DRG 909.
What is the ICD-9 procedure code for 02UT0JZ?
- The CMS GEMs map 02UT0JZ to ICD-9-CM 39.57 (Repair of blood vessel with synthetic patch graft).